Power System Protection Coordination

Proper protection coordination ensures that only the faulted portion of your electrical system is isolated during a fault, minimizing downtime and maintaining service to unaffected loads. Pythian Design provides comprehensive protection coordination studies with time-current curve analysis, relay settings, and coordination with utility protection schemes.

The Importance of Coordination

Selective Tripping: When a fault occurs, only the protective device immediately upstream of the fault should operate, leaving the rest of the system energized.

Minimize Downtime: Proper coordination limits outage extent, reducing lost production or service interruptions.

Equipment Protection: Correctly set protective devices prevent equipment damage from prolonged faults.

Safety: Coordination ensures backup protection operates if primary protection fails.

Time-Current Curve Analysis

We develop comprehensive time-current coordination (TCC) diagrams showing all protective devices.

Devices plotted include circuit breakers with relay characteristics, fuses, reclosers, and sectionalizers.

Coordination intervals verified per IEEE and industry standards (typically 0.2-0.4 seconds).

Motor contribution and distributed generation effects accounted for in fault calculations.

Utility coordination points identified and verified per utility requirements.

Standards & Compliance

IEEE 242 (Buff Book): IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems.
IEEE C37 Series: Relay and circuit breaker standards.
ANSI/IEEE Standards: Device numbers and protection functions.
Utility Protection Standards: Coordination with utility overcurrent, reclosing, and voltage protection.

What We Deliver

Short circuit analysis providing maximum and minimum fault currents
Time-current coordination curves (TCC diagrams) for all voltage levels
Relay settings for all protective relays (overcurrent, ground, directional)
Coordination tables showing time intervals between devices
Verification of selectivity throughout the system
Fuse selection and sizing where applicable
Motor protection coordination
Utility coordination verification
Protective device settings sheets ready for field implementation
PE-stamped report for utility and AHJ submittal

Why Choose Pythian Design

Comprehensive Analysis: We evaluate all protective devices and voltage levels for complete system coordination.
Utility Expertise: Deep understanding of utility protection philosophy and coordination requirements.
Practical Settings: Relay settings that provide protection while maintaining selectivity and minimizing nuisance tripping.
Clear Documentation: TCC diagrams and settings sheets that field technicians can easily implement.

Ready to Start Your Project?

Contact us today to discuss your power system protection coordination requirements and timeline.

Request a Consultation
JOIN THE TEAM

BUILD WITH US